The LF-AV-4125 Conventional Audible and Visual Alarm Indicator adopts a built-in integrated circuit, a piezoelectric sounder and a high intensity strobe which when combined, produces a high energy conversion efficiency for effective output of light and sound while utilizing a minimum amount of power.
The LF-AV-6125 Audible and Visual Alarm Indicator adopts a built-in integrated circuit, a piezoelectric sounder and a flasher which when combined, produces a high energy conversion efficiency for effective output of light and sound while utilizing a minimum amount of power. It is also directly connected to the detection loop of the Fire Panel to effectively monitor the device for faults or control for alarm activation.
آشکارساز دودی برای تشخیص دود در فضاهای بزرگ مانند سالن های، انبار، موزه ها، تئاتر و غیره طراحی شده که در آن تشخیص نقطه معمولی و یا غیر عملی پر هزینه تر است. این واحد مناسب برای کاربردهای که در آن نور شدید آفتاب یا منعکس است.تشخیص زود هنگام LE-SPB-24N باید در نظر گرفته شود. واحد تشخیص دود خطی در محدوده حفاظت شده را قادر می سازد .طراحی جمع و جور، به نظر می رسد خوب و نصب و راه اندازی نصب و راه اندازی خیط و پیت کردن باعث می شود این واحد ایده آل برای اتصالات در مناطق که در آن ملاحظات معماری مهم هستند.
The LF-HD-4112 Conventional Type Heat Detector identifies fire with both rapidly rising and gradually increasing temperature. It has three levels of fixed temperature settings to adapt itself to the local temperature of the area being protected.
The LF-SD-40 Battery Operated Smoke Detector uses a specialized smoke chamber design, which could sense the presence of smoke particles produced by fast combustion or slow smoldering fire. The detector can effectively sense both white smoke and black smoke with virtually no false alarms.
The LE-SLR-24V can be used in all areas where Photoelectric Smoke detectors are required. The wide range smoke chamber makes the LE-SLR-24V well suited for fires ranging from smoldering to flaming fires. LE-NS-4 Series, LE-NS-6 Series, LE-HSC-4R or LE-HSCxxx R Style bases may be used with the LE-SLR-24V. Current interchangeable/compatible devices are the LESIJ-24 ionization detector, the LE-SLR-24H photoelectric detector with heat sensor, and the LE-dCd-135/190 heat detectors. All LE-NS conventional devices are mechanically compatible with Lifeco LE-HSB, LE-HSC and LE-YBA type bases which may have been used in previous installations. Please check individual panel listings for compatible bases.
The LF/GD High Performance Gas Detector is used to detect various types of combustible gas. It is used mainly where there are possibilities of gas leakage like in chemical plants, gasoline stations, pharmaceutical factories, etc.
The LE-SLV-24V can be used in all areas where Photoelectric Smoke detectors are required. The patented smoke chamber makes the LE-SLV-24V well suited for fires ranging from smoldering to flaming fires. LE-NS4 Series, LE-NS6 Sereis, LE-HSC-4R or LE-HSCxxxR Style bases may be used with the LE-SLV-24V. Current interchangaeable/compatible devices are
The LF-DP-6190 Address Programmer is responsible for addressing fire alarm devices such as call points, detectors and modules connected in a loop. Up to 250 devices can be given identification per loop.
LFB series bells are intended for fire alarm application only. The gong is of cast alloy metal suitable to produce loud and standard alarm bell sound. Two gong sizes are available to suit high or low noise level applications.
The LF-CDI-6107 Conventional Zone Interface provides the means of connecting a single zone of conventional detectors to the Fire Alarm Control Panel. Typical connections would be conventional type smoke, heat, manual call point, heat sensing cables, and gas detectors. It can be used as an addressable alarm initiating device for conventional devices and as a control input for other auxiliary functions.
The LF-SI-6105 Signal Input Module provides the means of connecting Direct Shorting Devices to the Fire Alarm Control Panel. The module converts a normally open contact input which could monitor and report the status of the contact to the Fire Panel.
The LF-LI-6190 Short-Circuit Isolator provides short circuit protection on addressable device circuits. When a short is detected by the LF-LI-6190, it isolates the affected segment of the circuit, allowing the remaining devices to continue operation.
The LF-RM-6106 Relay Module provides the means of directly controlling an auxiliary device and its status as well. The Relay Module can be operated either by manual operation using switch inputs, or by automatic control using the Fire Panel logic functions.
The LF-CSW-6154 Remote Control Module provides the means of directly controlling an auxiliary device and its status as well. With its flexibility, the user has the option of either utilizing a normally open or normally close dry contact available on the module. It has the provision of connecting a normally open switch feedback input to monitor the status of the controlled auxiliary device.
The LF-CP Series Fire Alarm Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry and is designed and tested to meet the requirements of industrial or commercial applications. Up to 30 devices, combination of smoke, heat and manual call points, can be connected to a single zone. Any alarm coming from a zone would activate the sounder circuits, common alarm relay, zone relay and the panel audible circuit. Once the panel has been silenced and a subsequent alarm occurs in another zone, the internal speaker and sounder circuits would then re-activate with its associated zone relay.
The LF/EX Fire Alarm and Gas extinguishing Control Panel is manufactured based on advanced technology while maintaining high quality during assembly. It is of solid state circuitry and is designed and tested to meet the requirements of industrial or commercial applications.
The LF-6100A 1/2 distributed intelligent fire alarm control panel is a microprocessor based advanced detection and protection system. With its flexibility, unique design and ability to utilize both intelligent and conventional devices, makes it a very reliable system for life safety use. It adopts the use of a multi-line LCD screen for ease of viewing of events and controls, RTOS (Real Time Operating System), for real time monitoring and display of events, and a graphical display for user-friendly menu and control operation as well as ease of identifying information being sent by field devices to the Fire Alarm Controller.
The LF-6150 Repeater Panel is responsible for replicating fire and trouble information of a specific region from the Fire Control Unit. The device can monitor the alarm or the trouble state of 4 loops with up to 508 addressable points at most and display its information.
اسپرینکلر پایین زن
دمای عملکرد: 68°C
دارای تاییدیه UL آمریکا
The LF-PE-6101 intelligent type photo-electric smoke detector utilizes the light scatter sensing principle. It has an infrared light source, which emits signals and photo-diode, which senses the scattering light with the effect of smoke entering the chamber. The chamber is of light proof labyrinth type protected with thin metals mesh for protection from dust, insects and other external interferences.
کنترل پانل لایفکو LE-FN-2127 یک پانل آدرس پذیر آنالوگ اعلام حریق است که دارای 2 حلقه SLC می باشد. هر حلقه از 127 ترکیب دستگاه (سنسور یا ماژول)، و 127 دستگاه ساندر آنالوگ، تا سقف 254 نطقه تشکیل می شود.
اسپرینکلر بالا زن
دارای تاییدیه ULآمریکا
The LF-FD-6104 Intelligent UV Flame Detector has a wide angular sensitivity that can reliably and quickly detect the presence of a flame within its field of view by sensing the ultra violet radiation emitted.
کنترل پانل لایفکو LE-FN-4127 یک پانل آدرس پذیر آنالوگ اعلام حریق است که دارای 2 یا 4 حلقه SLC می باشد که هر حلقه از 127 ترکیب دستگاه (سنسور یا ماژول)، و 127 دستگاه ساندر آنالوگ، تا سقف 254 نطقه تشکیل می شود.
اسپرینکلر دیواری (Sidewall)
شبکه LCD هشدار دهنده مدل LE-FN-LCD-N برای استفاده در شبکه حریق طراحی شده است. این دستگاه قابل کنترل و هدایت از راه دور دارد و به همین دلیل می توانید از خارج از ساختمان نیز وضعیت حریق را کنترل نمایید. هشداردهنده مدل LE-FN-LCD-N یک هشداردهنده واقعی شبکه است که قابلیت هدایت، کنترل و دسترسی به همه پانل های شبکه را دارا می باشد. هر دستگاه مدل LE-FN-LCD-N بطور کاملا مستقل عمل می کند. رابط کاربری مستقیم و نمایشگر LCD 320 کارکتری مدل LE-FN-LCD-N دقیقا مشابه پانل شبکه حریق می باشد.
The LF-DB-LI isolating base is intended for use with the LF-6100 Series detectors. The LF-DB-LI isolating base senses and isolates short circuit faults on LF-6100 loops and spurs. In short-circuit conditions the integral red LED is illuminated.
اسپرینکلر پایین زن مخفی (Concealed)
The LF-HD-6102 intelligent heat detector provides an advanced method of detection, address programming and supervision, combined with sophisticated control panel communication. The detector uses a stateofthe-art thermistor providing 143°F (62°C) fixed temperature.
هشدار دهنده سریال مدل LE-FN-LCD-S یک راه حل مناسب و باصرفه را میسر می سازد. تا 15 عدد از هشداردهنده های LE-FN-LCD-S می توانند به درگاه RS485کنترل پانل شبکه حریق و یا شبکه هشداردهنده ها وصل شود. صفحه نمایش بزرگ 320 کارکتری و دکمه های هدایت یک پانل کنترل شبکه حریق کامل را بوجود آورده است. استفاده از رابط کاربری عادی، به کاربر اجازه می دهد، اگر قبلا بطور مستقیم با کنترل پانل شبکه حریق کار می کرده بتواند براحتی با LE-FN-LCD-S کار کند. امنیت با استفاده از پسورد یا کلید فعالساز "آتشنشان ها" تامین می شود. هشداردهنده مدل LE-FN-LCD-S با رعایت اصول هنری و زیباشناختی طراحی شده است و در رنگهای خاکستری و قرمز موجود می باشد.
The LF-MCP-6103 Manual Call Point has a 2 way communication with the Fire Alarm Control Panel thus making it an intelligent initiating device. With its sleek and durable design, it can be installed anywhere along corridors, hallways and exits for easy access to operate in cases where there is a requirement for manually activating an alarm signal.
شیر شبکه اسپرینکلر
ساخت کمپانی Lifeco انگلستان