The fire detector provides reliable early warning of a Fire condition upon ambient temperature reaching a fixed temperature threshold.
It is available in two versions (A2S or BS) depending on the temperature threshold in accordance with the European Standard EN54-5.
The fire detector is suitable for premises with normal or high ambient temperature, with possible sudden changes.
FD8020 Rate of rise heat detector
The fire detector provides reliable early warning of a Fire condition upon reaching a rate of rise of the temperature or fixed temperature threshold in the protected premises.It is available in two versions (A2R or BR) depending on the temperature threshold in accordance with the European Standard EN54-5. The fire detector is suitable for premises with normal ambient temperature, without possible sudden changes.
The fire detector provides reliable early warning of a Fire condition responding to fixed threshold smoke concentration or rate of rise of the temperature or fixed temperature threshold detected in the protected premises. It combines the advantages of a type FD8020 and a type FD8030 and it is an attractive option due to decreased expenses for supply and installation. The fire detector complies with the requirements of the European Standard EN54-5 (temperature class A2R) and EN54-7. Technical data
Optical flame fire detector FD 8040 is designed to provide early warning of a fire condition responding to open flame. The fire detector reacts within the light spectrum of the flame and has maximum sensitivity of the infrared range. The opearation principle is based on the reception of flame emissions with their typical flicker frequency within the whole spectrum range. The infrared sensor signal - amplified, filtered and shaped is being sent to the time delay circuit. If the flame impact has decreased during the time delay , the fire detector dos not activate.
Duct smoke detector YKB-02 is designed to detect the presence of smoke in airstream of ductwork sections or ventilating compartments by the smoke detector mounted in it.
The installation set АС 8001 is designed for external installation of Fire Detectors 7000 and 8000 Series. The set might be used with bases 8000, 8000D, 8000R, 8000RD, 7100, 7100A. ith bases 8000, 8000D, 8000R, 8000RD, 7100, 7100A. In most cases PVC or corrugated pipes are used for external installation of conducting wires. In this event the installation set AC In most cases PVC or corrugated pipes are used for external installation of conducting wires. In this event the installation set AC 8001 is required to be used. The intermediate base for external installation (pos. 1) allows for good connection of PVC or corrugated pipe to it. It provides enough space under the Fire detector base for the correct and convenient positioning of the connecting wires.
FD3050 Manual Call Point – It is designed to release a signal for a Fire condition to the Fire Control Panel upon manual activation by breaking the glass on the place, signed with arrows. The light indication for activating the manual call point is provided by a red LED. There is a possibility for testing by a special key.It satisfies the requirements of the European Standard EN54-11 for a type A manual call point.
Button EMERGENCY STOP
The button operates with Control Panel and holds extinguishing, increasing the evacuation time. It is to be installed close to the object of extinguishing.Fire alarm line is controlled for a short circuit and for an interruption.
Button MANUAL RELEASE
The button operates with Control Panel FS 5200E and activates the extinguishing.
It is to be installed close to the object of extinguishing.
By means of this button forced extinguishing process can be started only after visual inspection of an authorized person if a there is a real fire condition.
Fire alarm line is controlled for a short circuit and for an interruption.